Automatic irrigation filtration
Automatic Self-Cleaning Screen Filters
Continuous automatic filtration for irrigation systems, suspended solids and high-flow applications.
Technical values shown below are sourced from the 2026 manufacturer catalogue. Unlisted values are confirmed in the technical proposal.
Manufacturer catalogue: assembled screen filter
Quick technical overview
Source-backed selection range
Best applications
Where this system fits
Operating principle
How it works
Model selection
Verified catalogue models
Model codes and numerical values are reproduced from the supplied PDF. A final selection requires project review.
| Model | Connection / DN | Catalogue Flow (t/h) | Filtration Area (cm²) | Drain Port | Water / Cleaning (kg) | Motor (kW) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| SKY-L2 | DN50 | 25 | 3000 | DN25 | 50 | 0.18 | 90 |
| SKY-L2.5 | DN65 | 30 | 3000 | DN25 | 50 | 0.18 | 95 |
| SKY-L3 | DN80 | 60 | 3000 | DN25 | 50 | 0.18 | 99 |
| SKY-L4 | DN100 | 80 | 3000 | DN25 | 50 | 0.18 | 110 |
| SKY-L5 | DN125 | 120 | 3000 | DN25 | 50 | 0.18 | 116 |
| SKY-L6 | DN150 | 160 | 5900 | DN40 | 100 | 0.18 | 180 |
| SKY-L8 | DN200 | 300 | 5900 | DN50 | 160 | 0.18 | 190 |
| SKY-L10 | DN250 | 450 | 9500 | DN50 | 160 | 0.37 | 239 |
| SKY-L12 | DN300 | 650 | 9500 | DN50 | 160 | 0.37 | 270 |
| SKY-L14 | DN350 | 900 | 12000 | DN50 | 160 | 0.55 | 450 |
| SKY-L16 | DN400 | 1200 | 12000 | DN50 | 160 | 0.55 | 490 |
| SKY-L18 | DN450 | 1500 | 15000 | DN65 | 250 | 0.75 | 700 |
| SKY-L20 | DN500 | 2000 | 15000 | DN65 | 250 | 0.75 | 750 |
| SKY-L24 | DN600 | 2800 | 18000 | DN65 | 250 | 0.75 | 950 |
| Model | Connection / DN | Catalogue Flow (t/h) | Filtration Area (cm²) | Drain Port | Water / Cleaning (kg) | Motor (kW) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| SKY-T2 | DN50 | 25 | 3000 | DN25 | 50 | 0.18 | 92 |
| SKY-T2.5 | DN65 | 30 | 3000 | DN25 | 50 | 0.18 | 99 |
| SKY-T3 | DN80 | 60 | 3000 | DN25 | 50 | 0.18 | 108 |
| SKY-T4 | DN100 | 80 | 3000 | DN25 | 50 | 0.18 | 125 |
| SKY-T5 | DN125 | 120 | 3000 | DN25 | 50 | 0.18 | 135 |
| SKY-T6 | DN150 | 160 | 5900 | DN40 | 100 | 0.18 | 188 |
| SKY-T8 | DN200 | 300 | 5900 | DN40 | 100 | 0.18 | 208 |
| SKY-T10 | DN250 | 450 | 9500 | DN50 | 160 | 0.37 | 290 |
| SKY-T12 | DN300 | 650 | 9500 | DN50 | 160 | 0.37 | 325 |
| SKY-T14 | DN350 | 900 | 12000 | DN50 | 160 | 0.55 | 490 |
| SKY-T16 | DN400 | 1200 | 12000 | DN50 | 160 | 0.55 | 530 |
| SKY-T18 | DN450 | 1500 | 15000 | DN65 | 250 | 0.75 | 850 |
| SKY-T20 | DN500 | 2000 | 15000 | DN65 | 250 | 0.75 | 905 |
| SKY-T24 | DN600 | 2800 | 18000 | DN65 | 250 | 0.75 | 1110 |
| Model | Connection / DN | Catalogue Flow (t/h) | Filtration Area (cm²) | Drain Port | Water / Cleaning (kg) | Motor (kW) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| SKY-F2 | DN50 | 25 | 3000 | DN25 | 50 | 0.18 | 95 |
| SKY-F2.5 | DN65 | 30 | 3000 | DN25 | 50 | 0.18 | 100 |
| SKY-F3 | DN80 | 50 | 3000 | DN25 | 50 | 0.18 | 110 |
| SKY-F4 | DN100 | 80 | 3000 | DN25 | 50 | 0.18 | 115 |
| SKY-F5 | DN125 | 120 | 3000 | DN40 | 100 | 0.18 | 125 |
| SKY-F6 | DN150 | 160 | 5900 | DN40 | 100 | 0.18 | 175 |
| SKY-F8 | DN200 | 300 | 5900 | DN40 | 100 | 0.18 | 196 |
| SKY-F10 | DN250 | 450 | 9500 | DN50 | 160 | 0.37 | 290 |
| SKY-F12 | DN300 | 650 | 9500 | DN50 | 160 | 0.37 | 330 |
| Model | Connection / DN | Catalogue Flow (t/h) | Filtration Area (cm²) | Drain Port | Water / Cleaning (kg) | Motor (kW) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| SKY-Y2 | DN50 | 25 | 3000 | DN25 | 50 | 0.18 | 88 |
| SKY-Y2.5 | DN65 | 30 | 3000 | DN25 | 50 | 0.18 | 92 |
| SKY-Y3 | DN80 | 60 | 3000 | DN25 | 50 | 0.18 | 95 |
| SKY-Y4 | DN100 | 80 | 3000 | DN25 | 50 | 0.18 | 102 |
| SKY-Y5 | DN125 | 120 | 3000 | DN25 | 50 | 0.18 | 110 |
| SKY-Y6 | DN150 | 160 | 5900 | DN40 | 100 | 0.18 | 180 |
| SKY-Y8 | DN200 | 300 | 5900 | DN40 | 100 | 0.18 | 202 |
| SKY-Y10 | DN250 | 450 | 9500 | DN50 | 160 | 0.37 | 266 |
| SKY-Y12 | DN300 | 650 | 9500 | DN50 | 160 | 0.37 | 310 |
Configuration options
Build the system around the duty

The Application Defines the Configuration
This photograph illustrates the use context; it is not presented as a Delta AgriFlow installation. The system configuration is developed from project inputs.
- Water source and contaminant load
- Flow, pressure and connections
- Cleaning, drainage and maintenance
Downloads
Technical documentation
Technical FAQ
Questions before selection
How do I select the correct configuration?
Select the configuration after confirming connection size, required catalogue flow, filtration area, available pressure and installation arrangement.
What filtration degree is available?
The PDF does not state a filtration-degree range for the SKY family. It is confirmed in the technical proposal.
How much water is used in one cleaning cycle?
The source table lists 50, 100, 160 or 250 kg per cleaning depending on the model.
Can several units operate in parallel?
Parallel arrangements can be engineered when project flow or redundancy requires them.
Project selection
Not sure which configuration fits your project?
Send us your water source, flow rate or existing RFQ. Our team will review it with you.